Home >> Product >> Telephone Cable >> Special Telephone Cable |
| |
|
PE Insulated Air Core/Jelly Filled Star Quad Railway Signalling Cables (RF 0.1) |
|
| |
| Applications |
|
| |
The cables are designed to give good protection to the core against inductive interference (RF=0.1).The cables are used for outdoor signaling equipment. |
| Standards |
| |
• RENFE E.T. 03.365.051.6 |
| Construction |
|
| |
| Conductors: Solid annealed bare copper 0.9/1.4mm as per ASTM B-3/class 1 of IEC 60228. |
|
| Insulation: Solid polyethylene as per ASTM D 1248/IEC 60708. |
| Cabling Element: Four insulated conductors are twisted together to form a quad. |
| Cable Core Assembly: The cores are cabled together in concentric layers to form the cable core. Units are identified by colour coded binders. |
| Core Wrapping: One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap. |
| Electrostatic Screen: One layer of copper wires 0.12mm is applied helically. |
| Bedding: PE or LSZH. |
| Electrostatic Armour: Two steel tapes of 0.5mm are helically applied with gap. The outer tape will cover the gap left by the inner one. |
| Sheath: PE, PVC or LSZH. |
| Ripcord: Nylon ripcord may be placed parallel to the cores to facilitate sheath removal. |
|
|
| Electrical properties |
|
| |
| Nominal Conductor Diameter |
mm |
0.9 |
1.4 |
| Conductor Size |
mm2 |
0.636 |
1.539 |
| Maximum Conductor Resistance @20°C |
Ω/km |
28 |
12.1 |
| Minimum Insulation Resistance @500V DC |
MΩ.km |
35000 |
5000 |
| Reduction Factor Rk (50Hz) Induced Voltage Em 100V/Km |
|
0.1 |
0.1 |
| Induced Voltage Em 500V/Km |
|
0.16 |
0.16 |
| Maximum Resistance Unbalance |
% |
2.5 |
2.5 |
| Maximum Mutual Capacitance @0.8KHz |
nF/km |
45 |
50 |
| Maximum Capacitance Unbalance @1KHz pair-to-pair |
pF/500m |
250 |
250 |
| Maximum Capacitance Unbalance @1KHz pair-to-ground |
pF/500m |
1200 |
1200 |
| Maximum Average Attenuation @1KHz |
dB/km |
0.7 |
0.46 |
| Maximum Average Attenuation @10KHz |
dB/km |
1.6 |
0.85 |
| Maximum Average Attenuation @20KHz |
dB/km |
2.1 |
1.3 |
| Dielectric Strength Conductor to Conductor 3secs |
V DC |
3000 |
3000 |
| Conductor to Screen 3secs |
V DC |
3500 |
3500 |
| Minimum Insulation Thickness |
mm |
0.45 |
0.65 |
| Maximum Insulated Conductor Diameter |
mm |
1.8 |
2.7 |
|
|
| Mechanical and thermal properties |
| |
Temperature range during operation (fixed state) : -30°C – +70°C |
| |
Temperature range during installation (mobile state) : -20°C – +50°C |
| |
Minimum bending radius : 15 x Overall Diameter. |
| Colour Code |
| |
| Layer |
Quad Position |
Colour of conductors |
| 1 |
2 |
3 |
4 |
| Centre and even layers |
First |
ORANGE |
GREEN |
RED |
WHITE |
| Even |
YELLOW |
GREEN |
BLUE |
WHITE |
| Odd |
YELLOW |
GREEN |
RED |
WHITE |
| Last |
ORANGE |
GREEN |
BLUE |
WHITE |
| Odd Layers |
First |
ORANGE |
GREEN |
RED |
BLACK |
| Even |
YELLOW |
GREEN |
BLUE |
BLACK |
| Odd |
YELLOW |
GREEN |
RED |
BLACK |
| Last |
ORANGE |
GREEN |
BLUE |
BLACK |
|
|
| Dimensions and weight |
| |
| Cable Code |
Number of Quads |
Nominal Bedding/Sheath
Thickness mm |
Nominal Overall
Diameter mm |
Nominal Weight
kg/km |
| 0.9mm Conductor, 1.8mm Insulated Wire |
| TP365-2Y(CTS)2Y(DSTA)Y1Q09-RF01 |
1 |
1.5/1.6 |
24.5 |
1300 |
| TP365-2Y(CTS)2Y(DSTA)Y3Q09-RF01 |
3 |
1.5/1.6 |
25.5 |
1425 |
| TP365-2Y(CTS)2Y(DSTA)Y5Q09-RF01 |
5 |
1.5/1.6 |
28.0 |
1650 |
| TP365-2Y(CTS)2Y(DSTA)Y7Q09-RF01 |
7 |
1.5/1.6 |
29.5 |
1800 |
| TP365-2Y(CTS)2Y(DSTA)Y25Q09-RF01 |
25 |
1.7/1.8 |
41.0 |
3175 |
| 1.4mm Conductor, 2.7mm Insulated Wire |
| TP365-2Y(CTS)2Y(DSTA)Y3Q14-RF01 |
3 |
1.5/1.6 |
28.5 |
1775 |
| TP365-2Y(CTS)2Y(DSTA)Y5Q14-RF01 |
5 |
1.6/1.8 |
33.0 |
2200 |
| TP365-2Y(CTS)2Y(DSTA)Y7Q14-RF01 |
7 |
1.6/1.8 |
35.5 |
2525 |
| TP365-2Y(CTS)2Y(DSTA)Y10Q14-RF01 |
10 |
1.6/1.8 |
39.0 |
2975 |
|
| |
|